How to Check AC Capacitor: Electrician-Approved Guide
Air conditioning systems rely on capacitors to start compressors and fan motors efficiently. A failing capacitor is one of the most common AC problems homeowners encounter, often causing reduced cooling performance or complete system failure. Understanding how to check an AC capacitor can help you diagnose issues before calling a technician, potentially saving hundreds in service calls.
Capacitors store electrical energy and release it in controlled bursts to help motors overcome starting resistance. When a capacitor degrades, your AC unit struggles to maintain proper operation. This guide walks you through safe testing methods, warning signs of failure, and when to seek professional help. Whether you’re troubleshooting a window unit or a central system, these techniques apply across most residential AC installations.
Understanding AC Capacitors and Their Function
AC systems typically contain two types of capacitors: run capacitors and start capacitors. Run capacitors remain energized during the entire cooling cycle, helping maintain motor efficiency and smooth operation. Start capacitors provide an initial power surge when the compressor or fan motor first activates, then disconnect from the circuit. Some systems use dual-run capacitors that handle both functions simultaneously.
Capacitors are rated in microfarads (µF), a measurement of electrical storage capacity. Your AC unit’s capacitor specifications appear on the device label or in the equipment manual. Common residential AC capacitors range from 5 µF to 80 µF, with voltage ratings typically between 370V and 440V. Exceeding these ratings during operation causes rapid degradation and potential safety hazards.
The lifespan of a quality AC capacitor typically ranges from 10 to 20 years, though environmental factors like heat, humidity, and power surges can significantly reduce this timeline. Capacitors in hot climates deteriorate faster due to continuous thermal stress. Understanding your capacitor’s age and operating conditions helps predict potential failure.
Safety Precautions Before Testing
Never test a capacitor without proper safety preparation. Capacitors store dangerous electrical charges even when power is disconnected. Touching a charged capacitor can cause severe electrical shock, burns, or cardiac injury. Following these precautions protects you from serious harm:
- Turn off the AC unit’s power at the breaker and wait 5-10 minutes for residual charge to dissipate
- Use an insulated screwdriver to discharge the capacitor by touching both terminals simultaneously
- Wear safety glasses and insulated gloves rated for electrical work
- Use a properly calibrated multimeter with capacitance measurement capability
- Never work on a live circuit or skip the discharge step
- Keep one hand in your pocket when working with electrical components to prevent chest-crossing current paths
Many electricians recommend using a dedicated capacitor discharge tool rather than a screwdriver for additional safety. These tools provide controlled discharge without risk of arc flash or accidental contact with live terminals. If you’re uncomfortable with electrical testing, professional diagnosis remains the safest option.
Visual Inspection Methods
Before connecting testing equipment, perform a thorough visual inspection of the capacitor. Physical signs often reveal problems without requiring electrical testing. Look for these warning indicators:
- Bulging or swelling: The capacitor casing should be perfectly cylindrical. Any outward bulging indicates internal pressure buildup from fluid degradation
- Leaking fluid: A dark, oily residue around the base or sides means the capacitor is actively failing and should be replaced immediately
- Burn marks or discoloration: Dark spots or charred areas indicate internal electrical failure or external heat damage
- Cracked or split casing: Physical damage exposes internal components and creates electrical hazards
- Corrosion on terminals: White or green oxidation on metal terminals suggests moisture penetration and reduced electrical conductivity
Document any visual findings with photographs before proceeding. If you observe bulging, leaking, or burn marks, do not test the capacitor further. Schedule replacement immediately, as these units pose fire and electrical hazards. Even if testing shows the capacitor technically functions, visible damage warrants replacement.
Testing with a Multimeter
A digital multimeter with capacitance measurement mode provides the most accurate home testing method. This approach measures the capacitor’s actual microfarad value and compares it to the rated specification. Here’s the complete process:
Step 1: Prepare the Equipment
Select a multimeter with a capacitance (Cx or µF) setting. Analog meters lack this function, so digital multimeters are essential. Check that the meter’s capacitance range accommodates your capacitor’s rating. Most residential multimeters measure up to 200 µF, sufficient for standard AC units.
Step 2: Power Down and Discharge
Switch off the AC unit at the breaker. Wait at least 5-10 minutes for the system to de-energize completely. Using an insulated screwdriver, carefully touch both capacitor terminals simultaneously to discharge any remaining electrical charge. You may see a small spark—this is normal and indicates successful discharge.
Step 3: Remove the Capacitor (if accessible)
Some AC units allow safe capacitor testing in place, while others require removal. Consult your equipment manual or contact the manufacturer. If removing the capacitor, photograph the terminal connections before disconnection to ensure proper reinstallation. Use needle-nose pliers to gently remove spade terminals from the capacitor posts.
Step 4: Set Multimeter to Capacitance Mode
Rotate the multimeter dial to the capacitance setting (usually marked Cx or µF). Select the range closest to your capacitor’s rating without exceeding it. If uncertain, start with the highest capacitance range and work downward.
Step 5: Connect Test Leads
Insert the red probe into the positive terminal and the black probe into the negative terminal. Some capacitors have polarity markings; others are non-polarized. Maintain probe contact for 2-3 seconds while the meter stabilizes. The display will show the measured capacitance value.
Step 6: Compare to Specifications
The measured value should fall within 10% of the rated capacity. A capacitor rated 45 µF should measure between 40.5 and 49.5 µF to be considered functional. Values below this range indicate capacitor degradation. Values significantly above the rating suggest internal shorts.
If the meter displays “OL” (overload) or shows no reading, the capacitor is open-circuit and non-functional. This necessitates immediate replacement. Document the reading for your records and service technician reference.
Advanced Testing Techniques
Beyond basic multimeter testing, several advanced methods provide additional diagnostic information. These techniques require more specialized equipment and experience but offer comprehensive capacitor assessment.
ESR (Equivalent Series Resistance) Testing
ESR meters measure the internal resistance of a capacitor, revealing degradation that standard capacitance tests might miss. A capacitor can show correct microfarad values while exhibiting high ESR, indicating it cannot deliver current efficiently. ESR testing requires a dedicated meter, which costs $100-300 and is typically used by professional technicians. Values above 5 ohms generally indicate replacement necessity.
Voltage Decay Testing
This method charges the capacitor to a known voltage, then measures how quickly the charge dissipates. Healthy capacitors hold charge for extended periods, while failing units lose charge rapidly. This test requires an ESR meter with voltage decay capability and proper safety protocols to prevent shock hazards.
AC Impedance Analysis
Professional HVAC technicians use impedance analyzers that measure how the capacitor responds to varying frequencies. This reveals internal damage and contamination that affect performance under real-world operating conditions. These meters cost $500+ and require specialized training.
For most homeowners, basic multimeter testing provides sufficient diagnostic information. Advanced testing becomes valuable when multimeter results are inconclusive or when you want definitive assessment before expensive replacement.

Common Failure Signs
Recognizing capacitor failure symptoms helps you test proactively before complete system breakdown. These warning signs indicate your AC capacitor needs immediate attention:
- AC won’t start: The compressor or fan motor struggles to overcome starting resistance without adequate capacitor support
- Weak cooling performance: Reduced airflow or inability to reach desired temperatures suggests motor efficiency loss
- Humming sound from outdoor unit: A persistent hum without motor engagement indicates the compressor cannot start despite receiving power
- Frequent system cycling: The AC starts and stops repeatedly as thermal overload protection activates when motors overheat
- Burning smell: Electrical burning odors near the outdoor unit indicate capacitor internal failure and potential fire risk
- Tripped circuit breaker: Repeated breaker trips suggest the capacitor is creating electrical faults that overload the circuit
If you observe any of these symptoms, test the capacitor immediately. Many of these signs appear suddenly, giving little warning before complete failure. Addressing capacitor issues promptly prevents damage to compressors and motors, which cost significantly more to repair than capacitor replacement.

When to Replace vs When to Call a Professional
DIY Replacement Considerations
Capacitor replacement is one of the few AC maintenance tasks homeowners can safely perform. The procedure involves disconnecting the failed capacitor and installing an identical replacement. However, several factors should guide your decision:
Attempt DIY replacement only if you’re comfortable working with electrical components and have verified the capacitor specification matches your replacement unit exactly. Mismatched capacitance or voltage ratings create serious safety hazards and equipment damage. Always purchase replacements from reputable suppliers with manufacturer verification.
Professional Service Situations
Contact a licensed HVAC technician if you encounter these circumstances:
- Multiple capacitor failures within short timeframes, suggesting underlying electrical problems
- Inability to locate or safely access the capacitor in your AC unit
- Uncertainty about capacitor specifications or replacement procedures
- Warranty concerns—replacement by unauthorized personnel may void coverage
- Simultaneous motor or compressor damage requiring professional diagnosis
- Any situation where you feel uncomfortable working with electrical components
Professional technicians have the expertise to identify root causes of capacitor failure, such as electrical code violations or equipment incompatibilities. They also verify that replacement capacitors meet current safety standards and manufacturer specifications.
The cost of professional capacitor replacement typically ranges from $150-300, depending on your location and AC system complexity. This investment ensures proper installation and ongoing system reliability. Attempting repairs beyond your skill level risks expensive equipment damage and personal injury.
For additional electrical testing knowledge, review our guide on checking relays with a voltmeter, which uses similar safety protocols and diagnostic thinking. Understanding fuse testing with a voltmeter also builds valuable electrical troubleshooting skills applicable to capacitor work. Our comprehensive guide on checking capacitors with a multimeter provides additional detailed methodology.
FAQ
Can I test a capacitor while it’s still connected to the AC unit?
Testing an installed capacitor is possible but riskier than removal testing. The surrounding electrical components create additional hazard exposure. Always power down the unit and discharge the capacitor before any testing, whether installed or removed. Professional technicians sometimes test in-place capacitors, but they have specialized equipment and extensive experience. For your safety, removal before testing is recommended.
What does “out of spec” mean on a capacitor test?
Out-of-spec refers to measured values falling outside the acceptable 10% range of the rated microfarad specification. A capacitor measuring significantly below its rating cannot provide adequate motor support and should be replaced. Values above specification indicate internal electrical problems and also warrant replacement. Only readings within the 10% acceptable range indicate functional capacitors.
Why do capacitors fail prematurely?
Environmental stress causes accelerated capacitor degradation. Excessive heat from outdoor unit exposure, humidity infiltration, power surges from lightning or utility issues, and manufacturing defects all shorten lifespan. Units in hot climates experience 30-50% shorter capacitor life than those in moderate climates. Protecting your outdoor AC unit with shade and surge protection extends capacitor longevity.
Is it safe to run my AC if the capacitor tests low?
Running an AC system with a failing capacitor risks serious damage. Motors operating without adequate capacitor support draw excessive current, causing overheating and burnout. This transforms a $200 capacitor replacement into a $1,500+ compressor replacement. Additionally, stressed motors create fire hazards and electrical faults. Replace failed capacitors immediately rather than operating with degraded units.
How do I know which capacitor type my AC system uses?
Check the equipment nameplate on your outdoor AC unit, which lists all component specifications including capacitor type and rating. Your system’s installation manual provides detailed electrical diagrams and capacitor information. If you cannot locate this documentation, contact your equipment manufacturer with your unit’s model and serial number. Never guess at capacitor specifications—incorrect replacements create hazardous conditions.
Can I use a higher voltage-rated capacitor as a replacement?
Using a higher voltage-rated capacitor is technically safe but unnecessary and wasteful. A capacitor rated 440V works in a 370V system without problems—the unit simply operates below its maximum voltage. However, the reverse is dangerous: installing a lower voltage-rated capacitor in a higher voltage system causes immediate failure and potential explosion. Always match or exceed the voltage rating, never go below it. Match the microfarad rating exactly.